In the current process, the management table is missing after the
IMP reset. This patch adds the management table to the reset process.
Fixes: bb8d537acd5e ("net: hns3: add manager table initialization for hardware")
Signed-off-by: Yufeng Mo <moyufeng@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
return ret;
}
+ ret = init_mgr_tbl(hdev);
+ if (ret) {
+ dev_err(&pdev->dev,
+ "failed to reinit manager table, ret = %d\n", ret);
+ return ret;
+ }
+
ret = hclge_init_fd_config(hdev);
if (ret) {
dev_err(&pdev->dev, "fd table init fail, ret=%d\n", ret);