i40e: Fix call trace in setup_tx_descriptors
authorAleksandr Loktionov <aleksandr.loktionov@intel.com>
Thu, 19 May 2022 14:01:45 +0000 (16:01 +0200)
committerTony Nguyen <anthony.l.nguyen@intel.com>
Thu, 9 Jun 2022 15:54:19 +0000 (08:54 -0700)
After PF reset and ethtool -t there was call trace in dmesg
sometimes leading to panic. When there was some time, around 5
seconds, between reset and test there were no errors.

Problem was that pf reset calls i40e_vsi_close in prep_for_reset
and ethtool -t calls i40e_vsi_close in diag_test. If there was not
enough time between those commands the second i40e_vsi_close starts
before previous i40e_vsi_close was done which leads to crash.

Add check to diag_test if pf is in reset and don't start offline
tests if it is true.
Add netif_info("testing failed") into unhappy path of i40e_diag_test()

Fixes: f6d7cf4d42bd ("i40e: Disable offline diagnostics if VFs are enabled")
Fixes: 7cd7df842ad1 ("i40e: Fix ethtool offline diagnostic with netqueues")
Signed-off-by: Michal Jaron <michalx.jaron@intel.com>
Signed-off-by: Aleksandr Loktionov <aleksandr.loktionov@intel.com>
Tested-by: Gurucharan <gurucharanx.g@intel.com> (A Contingent worker at Intel)
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>
drivers/net/ethernet/intel/i40e/i40e_ethtool.c

index 610f00cbaff9857cccb127741477293821270ee2..19704f5c8291c7ca1ec5f492d50542bdee8faa9b 100644 (file)
@@ -2586,15 +2586,16 @@ static void i40e_diag_test(struct net_device *netdev,
 
                set_bit(__I40E_TESTING, pf->state);
 
+               if (test_bit(__I40E_RESET_RECOVERY_PENDING, pf->state) ||
+                   test_bit(__I40E_RESET_INTR_RECEIVED, pf->state)) {
+                       dev_warn(&pf->pdev->dev,
+                                "Cannot start offline testing when PF is in reset state.\n");
+                       goto skip_ol_tests;
+               }
+
                if (i40e_active_vfs(pf) || i40e_active_vmdqs(pf)) {
                        dev_warn(&pf->pdev->dev,
                                 "Please take active VFs and Netqueues offline and restart the adapter before running NIC diagnostics\n");
-                       data[I40E_ETH_TEST_REG]         = 1;
-                       data[I40E_ETH_TEST_EEPROM]      = 1;
-                       data[I40E_ETH_TEST_INTR]        = 1;
-                       data[I40E_ETH_TEST_LINK]        = 1;
-                       eth_test->flags |= ETH_TEST_FL_FAILED;
-                       clear_bit(__I40E_TESTING, pf->state);
                        goto skip_ol_tests;
                }
 
@@ -2641,9 +2642,17 @@ static void i40e_diag_test(struct net_device *netdev,
                data[I40E_ETH_TEST_INTR] = 0;
        }
 
-skip_ol_tests:
-
        netif_info(pf, drv, netdev, "testing finished\n");
+       return;
+
+skip_ol_tests:
+       data[I40E_ETH_TEST_REG]         = 1;
+       data[I40E_ETH_TEST_EEPROM]      = 1;
+       data[I40E_ETH_TEST_INTR]        = 1;
+       data[I40E_ETH_TEST_LINK]        = 1;
+       eth_test->flags |= ETH_TEST_FL_FAILED;
+       clear_bit(__I40E_TESTING, pf->state);
+       netif_info(pf, drv, netdev, "testing failed\n");
 }
 
 static void i40e_get_wol(struct net_device *netdev,