err = __mmc_switch(card, EXT_CSD_CMD_SET_NORMAL,
EXT_CSD_HS_TIMING, EXT_CSD_TIMING_HS,
card->ext_csd.generic_cmd6_time, MMC_TIMING_MMC_HS,
- true, true, true);
+ true, true);
if (err)
pr_warn("%s: switch to high-speed failed, err:%d\n",
mmc_hostname(card->host), err);
ext_csd_bits,
card->ext_csd.generic_cmd6_time,
MMC_TIMING_MMC_DDR52,
- true, true, true);
+ true, true);
if (err) {
pr_err("%s: switch to bus width %d ddr failed\n",
mmc_hostname(host), 1 << bus_width);
err = __mmc_switch(card, EXT_CSD_CMD_SET_NORMAL,
EXT_CSD_HS_TIMING, val,
card->ext_csd.generic_cmd6_time, 0,
- true, false, true);
+ false, true);
if (err) {
pr_err("%s: switch to high-speed from hs200 failed, err:%d\n",
mmc_hostname(host), err);
err = __mmc_switch(card, EXT_CSD_CMD_SET_NORMAL,
EXT_CSD_HS_TIMING, val,
card->ext_csd.generic_cmd6_time, 0,
- true, false, true);
+ false, true);
if (err) {
pr_err("%s: switch to hs400 failed, err:%d\n",
mmc_hostname(host), err);
val = EXT_CSD_TIMING_HS;
err = __mmc_switch(card, EXT_CSD_CMD_SET_NORMAL, EXT_CSD_HS_TIMING,
val, card->ext_csd.generic_cmd6_time, 0,
- true, false, true);
+ false, true);
if (err)
goto out_err;
/* Switch HS DDR to HS */
err = __mmc_switch(card, EXT_CSD_CMD_SET_NORMAL, EXT_CSD_BUS_WIDTH,
EXT_CSD_BUS_WIDTH_8, card->ext_csd.generic_cmd6_time,
- 0, true, false, true);
+ 0, false, true);
if (err)
goto out_err;
card->drive_strength << EXT_CSD_DRV_STR_SHIFT;
err = __mmc_switch(card, EXT_CSD_CMD_SET_NORMAL, EXT_CSD_HS_TIMING,
val, card->ext_csd.generic_cmd6_time, 0,
- true, false, true);
+ false, true);
if (err)
goto out_err;
err = __mmc_switch(card, EXT_CSD_CMD_SET_NORMAL,
EXT_CSD_HS_TIMING, EXT_CSD_TIMING_HS,
card->ext_csd.generic_cmd6_time, 0,
- true, false, true);
+ false, true);
if (err) {
pr_err("%s: switch to hs for hs400es failed, err:%d\n",
mmc_hostname(host), err);
err = __mmc_switch(card, EXT_CSD_CMD_SET_NORMAL,
EXT_CSD_HS_TIMING, val,
card->ext_csd.generic_cmd6_time, 0,
- true, false, true);
+ false, true);
if (err) {
pr_err("%s: switch to hs400es failed, err:%d\n",
mmc_hostname(host), err);
err = __mmc_switch(card, EXT_CSD_CMD_SET_NORMAL,
EXT_CSD_HS_TIMING, val,
card->ext_csd.generic_cmd6_time, 0,
- true, false, true);
+ false, true);
if (err)
goto err;
old_timing = host->ios.timing;
err = __mmc_switch(card, EXT_CSD_CMD_SET_NORMAL,
EXT_CSD_POWER_OFF_NOTIFICATION,
- notify_type, timeout, 0, true, false, false);
+ notify_type, timeout, 0, false, false);
if (err)
pr_err("%s: Power Off Notification timed out, %u\n",
mmc_hostname(card->host), timeout);
* @timeout_ms: timeout (ms) for operation performed by register write,
* timeout of zero implies maximum possible timeout
* @timing: new timing to change to
- * @use_busy_signal: use the busy signal as response type
* @send_status: send status cmd to poll for busy
* @retry_crc_err: retry when CRC errors when polling with CMD13 for busy
*
*/
int __mmc_switch(struct mmc_card *card, u8 set, u8 index, u8 value,
unsigned int timeout_ms, unsigned char timing,
- bool use_busy_signal, bool send_status, bool retry_crc_err)
+ bool send_status, bool retry_crc_err)
{
struct mmc_host *host = card->host;
int err;
struct mmc_command cmd = {};
- bool use_r1b_resp = use_busy_signal;
+ bool use_r1b_resp = true;
unsigned char old_timing = host->ios.timing;
mmc_retune_hold(host);
if (err)
goto out;
- /* No need to check card status in case of unblocking command */
- if (!use_busy_signal)
- goto out;
-
/*If SPI or used HW busy detection above, then we don't need to poll. */
if (((host->caps & MMC_CAP_WAIT_WHILE_BUSY) && use_r1b_resp) ||
mmc_host_is_spi(host))
unsigned int timeout_ms)
{
return __mmc_switch(card, set, index, value, timeout_ms, 0,
- true, true, false);
+ true, false);
}
EXPORT_SYMBOL_GPL(mmc_switch);