The sja1105_gating_cfg_time_to_interval function does this, as per the
comments:
/* The gate entries contain absolute times in their e->interval field. Convert
* that to proper intervals (i.e. "0, 5, 10, 15" to "5, 5, 5, 5").
*/
To perform that task, it iterates over gating_cfg->entries, at each step
updating the interval of the _previous_ entry. So one interval remains
to be updated at the end of the loop: the last one (since it isn't
"prev" for anyone else).
But there was an erroneous check, that the last element's interval
should not be updated if it's also the only element. I'm not quite sure
why that check was there, but it's clearly incorrect, as a tc-gate
schedule with a single element would get an e->interval of zero,
regardless of the duration requested by the user. The switch wouldn't
even consider this configuration as valid: it will just drop all traffic
that matches the rule.
Fixes: 83ed1d663245 ("net: dsa: sja1105: implement tc-gate using time-triggered virtual links")
Reported-by: Xiaoliang Yang <xiaoliang.yang_1@nxp.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
}
last_e = list_last_entry(&gating_cfg->entries,
struct sja1105_gate_entry, list);
- if (last_e->list.prev != &gating_cfg->entries)
- last_e->interval = cycle_time - last_e->interval;
+ last_e->interval = cycle_time - last_e->interval;
}
static void sja1105_free_gating_config(struct sja1105_gating_config *gating_cfg)