Internal registers in SPL are at address 0xd0000000 and in proper U-Boot at
address 0xf1000000. UART base address is located in internal registers.
Fix DEBUG_UART_BASE option to correct value for both SPL and proper U-Boot.
This change fixes hangup of proper U-Boot when it is trying to print
something via debug UART.
Signed-off-by: Pali Rohár <pali@kernel.org>
Reviewed-by: Stefan Roese <sr@denx.de>
CONFIG_SPL_TEXT_BASE=0x40000030
CONFIG_SPL_SERIAL=y
CONFIG_SPL=y
-CONFIG_DEBUG_UART_BASE=0xd0012000
+CONFIG_DEBUG_UART_BASE=0xf1012000
CONFIG_DEBUG_UART_CLOCK=250000000
CONFIG_SYS_LOAD_ADDR=0x800000
CONFIG_DEBUG_UART=y
CONFIG_DM_RTC=y
CONFIG_RTC_ARMADA38X=y
CONFIG_SCSI=y
+CONFIG_SPL_DEBUG_UART_BASE=0xd0012000
CONFIG_DEBUG_UART_SHIFT=2
CONFIG_SYS_NS16550=y
CONFIG_KIRKWOOD_SPI=y