[Why]
The default value for disable_dmcu is true, even for asics that require
dmcu.
[How]
Set flag properly per asic.
Signed-off-by: Wyatt Wood <wyatt.wood@amd.com>
Reviewed-by: Nicholas Kazlauskas <Nicholas.Kazlauskas@amd.com>
Acked-by: Rodrigo Siqueira <Rodrigo.Siqueira@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
static const struct dc_debug_options debug_defaults_drv = {
.sanity_checks = true,
- .disable_dmcu = true,
+ .disable_dmcu = false,
.force_abm_enable = false,
.timing_trace = false,
.clock_trace = true,
};
static const struct dc_debug_options debug_defaults_diags = {
- .disable_dmcu = true,
+ .disable_dmcu = false,
.force_abm_enable = false,
.timing_trace = true,
.clock_trace = true,
};
static const struct dc_debug_options debug_defaults_drv = {
- .disable_dmcu = true,
+ .disable_dmcu = false,
.force_abm_enable = false,
.timing_trace = false,
.clock_trace = true,
};
static const struct dc_debug_options debug_defaults_diags = {
- .disable_dmcu = true,
+ .disable_dmcu = false,
.force_abm_enable = false,
.timing_trace = true,
.clock_trace = true,
};
static const struct dc_debug_options debug_defaults_drv = {
- .disable_dmcu = true,
+ .disable_dmcu = false,
.force_abm_enable = false,
.timing_trace = false,
.clock_trace = true,
};
static const struct dc_debug_options debug_defaults_diags = {
- .disable_dmcu = true,
+ .disable_dmcu = false,
.force_abm_enable = false,
.timing_trace = true,
.clock_trace = true,