Move the setting of the filter-sync-needed bit to the error
case in the filter add routine to be sure we're checking the
live filter status rather than a copy of the pre-sync status.
Fixes: 969f84394604 ("ionic: sync the filters in the work task")
Signed-off-by: Shannon Nelson <snelson@pensando.io>
Signed-off-by: David S. Miller <davem@davemloft.net>
if (err && err != -EEXIST) {
/* set the state back to NEW so we can try again later */
f = ionic_rx_filter_by_addr(lif, addr);
- if (f && f->state == IONIC_FILTER_STATE_SYNCED)
+ if (f && f->state == IONIC_FILTER_STATE_SYNCED) {
f->state = IONIC_FILTER_STATE_NEW;
+ set_bit(IONIC_LIF_F_FILTER_SYNC_NEEDED, lif->state);
+ }
spin_unlock_bh(&lif->rx_filters.lock);
list_for_each_entry_safe(sync_item, spos, &sync_add_list, list) {
(void)ionic_lif_addr_add(lif, sync_item->f.cmd.mac.addr);
- if (sync_item->f.state != IONIC_FILTER_STATE_SYNCED)
- set_bit(IONIC_LIF_F_FILTER_SYNC_NEEDED, lif->state);
-
list_del(&sync_item->list);
devm_kfree(dev, sync_item);
}