]> git.baikalelectronics.ru Git - kernel.git/commitdiff
net: dsa: microchip: lan937x: fix maximum frame length check
authorRakesh Sankaranarayanan <rakesh.sankaranarayanan@microchip.com>
Mon, 12 Sep 2022 05:12:28 +0000 (10:42 +0530)
committerPaolo Abeni <pabeni@redhat.com>
Tue, 20 Sep 2022 10:01:51 +0000 (12:01 +0200)
Maximum frame length check is enabled in lan937x switch on POR, But it
is found to be disabled on driver during port setup operation. Due to
this, packets are not dropped when transmitted with greater than configured
value. For testing, setup made for lan1->lan2 transmission and configured
lan1 interface with a frame length (less than 1500 as mentioned in
documentation) and transmitted packets with greater than configured value.
Expected no packets at lan2 end, but packets observed at lan2.

Based on the documentation, packets should get discarded if the actual
packet length doesn't match the frame length configured. Frame length check
should be disabled only for cascaded ports due to tailtags.

This feature was disabled on ksz9477 series due to ptp issue, which is
not in lan937x series. But since lan937x took ksz9477 as base, frame
length check disabled here as well. Patch added to remove this portion
from port setup so that maximum frame length check will be active for
normal ports.

Fixes: bc996dd0fac1 ("net: dsa: microchip: add DSA support for microchip LAN937x")
Signed-off-by: Rakesh Sankaranarayanan <rakesh.sankaranarayanan@microchip.com>
Link: https://lore.kernel.org/r/20220912051228.1306074-1-rakesh.sankaranarayanan@microchip.com
Signed-off-by: Paolo Abeni <pabeni@redhat.com>
drivers/net/dsa/microchip/lan937x_main.c

index daedd2bf20c1b6a7746cdd6ed495f2582c389836..5579644e8fde447a649c2310ff4e923999ff2e48 100644 (file)
@@ -244,10 +244,6 @@ void lan937x_port_setup(struct ksz_device *dev, int port, bool cpu_port)
                lan937x_port_cfg(dev, port, REG_PORT_CTRL_0,
                                 PORT_TAIL_TAG_ENABLE, true);
 
-       /* disable frame check length field */
-       lan937x_port_cfg(dev, port, REG_PORT_MAC_CTRL_0, PORT_CHECK_LENGTH,
-                        false);
-
        /* set back pressure for half duplex */
        lan937x_port_cfg(dev, port, REG_PORT_MAC_CTRL_1, PORT_BACK_PRESSURE,
                         true);