The clock ouput frequency is calculated incorrectly for AR8035 due to
wrong masking of priv->clk_25m_reg and priv->clk_25m_mask.
This same issue has been already fixed in the kernel by:
commit
b1f4c209d84057b6d40b939b6e4404854271d797
Author: Oleksij Rempel <o.rempel@pengutronix.de>
Date: Wed Apr 1 11:57:32 2020 +0200
net: phy: at803x: fix clock sink configuration on ATH8030 and ATH8035
The masks in priv->clk_25m_reg and priv->clk_25m_mask are one-bits-set
for the values that comprise the fields, not zero-bits-set.
This patch fixes the clock frequency configuration for ATH8030 and
ATH8035 Atheros PHYs by removing the erroneous "~".
To reproduce this bug, configure the PHY with the device tree binding
"qca,clk-out-frequency" and remove the machine specific PHY fixups.
Fixes: 2f664823a47021 ("net: phy: at803x: add device tree binding")
Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
Reported-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Russell King <rmk+kernel@armlinux.org.uk>
Tested-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
Apply the same fix in the U-Boot driver.
Tested on a i.MX6 Hummingboard.
Signed-off-by: Fabio Estevam <festevam@gmail.com>
Reviewed-by: Michael Walle <michael@walle.cc>
Tested-by: Tom Rini <trini@konsulko.com>
* Fixup for the AR8035 which only has two bits. The two
* remaining bits map to the same frequencies.
*/
- if (phydev->drv->uid == AR8035_PHY_ID) {
- u16 clear = AR803x_CLK_25M_MASK & AR8035_CLK_25M_MASK;
- priv->clk_25m_mask &= ~clear;
- priv->clk_25m_reg &= ~clear;
+ if (phydev->drv->uid == AR8035_PHY_ID) {
+ priv->clk_25m_reg &= AR8035_CLK_25M_MASK;
+ priv->clk_25m_mask &= AR8035_CLK_25M_MASK;
}
}