thermal: intel: int340x: Protect trip temperature from concurrent updates
commit
6757a7abe47bcb12cb2d45661067e182424b0ee3 upstream.
Trip temperatures are read using ACPI methods and stored in the memory
during zone initializtion and when the firmware sends a notification for
change. This trip temperature is returned when the thermal core calls via
callback get_trip_temp().
But it is possible that while updating the memory copy of the trips when
the firmware sends a notification for change, thermal core is reading the
trip temperature via the callback get_trip_temp(). This may return invalid
trip temperature.
To address this add a mutex to protect the invalid temperature reads in
the callback get_trip_temp() and int340x_thermal_read_trips().
Fixes: c6f47ab05910 ("Thermal/int340x: Add common thermal zone handler")
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Cc: 5.0+ <stable@vger.kernel.org> # 5.0+
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>