net: mscc: ocelot: only drain extraction queue on error
It appears that the intention of this snippet of code is to not exit
ocelot_xtr_irq_handler() while in the middle of extracting a frame.
The problem in extracting it word by word is that future extraction
attempts are really easy to get desynchronized, since the IRQ handler
assumes that the first 16 bytes are the IFH, which give further
information about the frame, such as frame length.
But during normal operation, "err" will not be 0, but 4, set from here:
for (i = 0; i < OCELOT_TAG_LEN / 4; i++) {
err = ocelot_rx_frame_word(ocelot, grp, true, &ifh[i]);
if (err != 4)
break;
}
if (err != 4)
break;
In that case, draining the extraction queue is a no-op. So explicitly
make this code execute only on negative err.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Reviewed-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>