net/smc: fix 'workqueue leaked lock' in smc_conn_abort_work
The abort_work is scheduled when a connection was detected to be
out-of-sync after a link failure. The work calls smc_conn_kill(),
which calls smc_close_active_abort() and that might end up calling
smc_close_cancel_work().
smc_close_cancel_work() cancels any pending close_work and tx_work but
needs to release the sock_lock before and acquires the sock_lock again
afterwards. So when the sock_lock was NOT acquired before then it may
be held after the abort_work completes. Thats why the sock_lock is
acquired before the call to smc_conn_kill() in __smc_lgr_terminate(),
but this is missing in smc_conn_abort_work().
Fix that by acquiring the sock_lock first and release it after the
call to smc_conn_kill().
Fixes: b286a0651e44 ("net/smc: handle incoming CDC validation message") Signed-off-by: Karsten Graul <kgraul@linux.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>