pwm: crc: Fix off-by-one error in the clock-divider calculations
The CRC PWM controller has a clock-divider which divides the clock with
a value between 1-128. But as can seen from the PWM_DIV_CLK_xxx
defines, this range maps to a register value of 0-127.
So after calculating the clock-divider we must subtract 1 to get the
register value, unless the requested frequency was so high that the
calculation has already resulted in a (rounded) divider value of 0.
Note that before this fix, setting a period of PWM_MAX_PERIOD_NS which
corresponds to the max. divider value of 128 could have resulted in a
bug where the code would use 128 as divider-register value which would
have resulted in an actual divider value of 0 (and the enable bit being
set). A rounding error stopped this bug from actually happen. This
same rounding error means that after the subtraction of 1 it is impossible
to set the divider to 128. Also bump PWM_MAX_PERIOD_NS by 1 ns to allow
setting a divider of 128 (register-value 127).
Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Acked-by: Thierry Reding <thierry.reding@gmail.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Link: https://patchwork.freedesktop.org/patch/msgid/20200903112337.4113-10-hdegoede@redhat.com