scsi: BusLogic: Fix missing pr_cont() use
commit
44d01fc86d952f5a8b8b32bdb4841504d5833d95 upstream.
Update BusLogic driver's messaging system to use pr_cont() for continuation
lines, bringing messy output:
pci 0000:00:13.0: PCI->APIC IRQ transform: INT A -> IRQ 17
scsi: ***** BusLogic SCSI Driver Version 2.1.17 of 12 September 2013 *****
scsi: Copyright 1995-1998 by Leonard N. Zubkoff <lnz@dandelion.com>
scsi0: Configuring BusLogic Model BT-958 PCI Wide Ultra SCSI Host Adapter
scsi0: Firmware Version: 5.07B, I/O Address: 0x7000, IRQ Channel: 17/Level
scsi0: PCI Bus: 0, Device: 19, Address:
0xE0012000,
Host Adapter SCSI ID: 7
scsi0: Parity Checking: Enabled, Extended Translation: Enabled
scsi0: Synchronous Negotiation: Ultra, Wide Negotiation: Enabled
scsi0: Disconnect/Reconnect: Enabled, Tagged Queuing: Enabled
scsi0: Scatter/Gather Limit: 128 of 8192 segments, Mailboxes: 211
scsi0: Driver Queue Depth: 211, Host Adapter Queue Depth: 192
scsi0: Tagged Queue Depth:
Automatic
, Untagged Queue Depth: 3
scsi0: SCSI Bus Termination: Both Enabled
, SCAM: Disabled
scsi0: *** BusLogic BT-958 Initialized Successfully ***
scsi host0: BusLogic BT-958
back to order:
pci 0000:00:13.0: PCI->APIC IRQ transform: INT A -> IRQ 17
scsi: ***** BusLogic SCSI Driver Version 2.1.17 of 12 September 2013 *****
scsi: Copyright 1995-1998 by Leonard N. Zubkoff <lnz@dandelion.com>
scsi0: Configuring BusLogic Model BT-958 PCI Wide Ultra SCSI Host Adapter
scsi0: Firmware Version: 5.07B, I/O Address: 0x7000, IRQ Channel: 17/Level
scsi0: PCI Bus: 0, Device: 19, Address: 0xE0012000, Host Adapter SCSI ID: 7
scsi0: Parity Checking: Enabled, Extended Translation: Enabled
scsi0: Synchronous Negotiation: Ultra, Wide Negotiation: Enabled
scsi0: Disconnect/Reconnect: Enabled, Tagged Queuing: Enabled
scsi0: Scatter/Gather Limit: 128 of 8192 segments, Mailboxes: 211
scsi0: Driver Queue Depth: 211, Host Adapter Queue Depth: 192
scsi0: Tagged Queue Depth: Automatic, Untagged Queue Depth: 3
scsi0: SCSI Bus Termination: Both Enabled, SCAM: Disabled
scsi0: *** BusLogic BT-958 Initialized Successfully ***
scsi host0: BusLogic BT-958
Also diagnostic output such as with the BusLogic=TraceConfiguration
parameter is affected and becomes vertical and therefore hard to read.
This has now been corrected, e.g.:
pci 0000:00:13.0: PCI->APIC IRQ transform: INT A -> IRQ 17
blogic_cmd(86) Status = 30: 4 ==> 4: FF 05 93 00
blogic_cmd(95) Status = 28: (Modify I/O Address)
blogic_cmd(91) Status = 30: 1 ==> 1: 01
blogic_cmd(04) Status = 30: 4 ==> 4: 41 41 35 30
blogic_cmd(8D) Status = 30: 14 ==> 14: 45 DC 00 20 00 00 00 00 00 40 30 37 42 1D
scsi: ***** BusLogic SCSI Driver Version 2.1.17 of 12 September 2013 *****
scsi: Copyright 1995-1998 by Leonard N. Zubkoff <lnz@dandelion.com>
blogic_cmd(04) Status = 30: 4 ==> 4: 41 41 35 30
blogic_cmd(0B) Status = 30: 3 ==> 3: 00 08 07
blogic_cmd(0D) Status = 30: 34 ==> 34: 03 01 07 04 00 00 00 00 00 00 00 00 00 00 00 00 FF 42 44 46 FF 00 00 00 00 00 00 00 00 00 FF 00 FF 00
blogic_cmd(8D) Status = 30: 14 ==> 14: 45 DC 00 20 00 00 00 00 00 40 30 37 42 1D
blogic_cmd(84) Status = 30: 1 ==> 1: 37
blogic_cmd(8B) Status = 30: 5 ==> 5: 39 35 38 20 20
blogic_cmd(85) Status = 30: 1 ==> 1: 42
blogic_cmd(86) Status = 30: 4 ==> 4: FF 05 93 00
blogic_cmd(91) Status = 30: 64 ==> 64: 41 46 3E 20 39 35 38 20 20 00 C4 00 04 01 07 2F 07 04 35 FF FF FF FF FF FF FF FF FF FF 01 00 FE FF 08 FF FF 00 00 00 00 00 00 00 01 00 01 00 00 FF FF 00 00 00 00 00 00 00 00 00 00 00 00 00 FC
scsi0: Configuring BusLogic Model BT-958 PCI Wide Ultra SCSI Host Adapter
etc.
Link: https://lore.kernel.org/r/alpine.DEB.2.21.2104201940430.44318@angie.orcam.me.uk
Fixes: 3c758df09457 ("printk: reinstate KERN_CONT for printing continuation lines")
Cc: stable@vger.kernel.org # v4.9+
Acked-by: Khalid Aziz <khalid@gonehiking.org>
Signed-off-by: Maciej W. Rozycki <macro@orcam.me.uk>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>