When changing network interface settings, Windows guests
older than WS2016 can no longer shutdown. This was addressed
by commit
1e036cd3c68e7 ("hv_netvsc: change GPAD teardown order
on older versions"), however the issue also occurs on WS2012
guests that share NVSP protocol versions with WS2016 guests.
Hence we use Windows version directly to differentiate them.
Fixes: 1e036cd3c68e7 ("hv_netvsc: change GPAD teardown order on older versions")
Signed-off-by: Mohammed Gamal <mgamal@redhat.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
netdev_dbg(ndev, "net device safe to remove\n");
/* older versions require that buffer be revoked before close */
- if (net_device->nvsp_version < NVSP_PROTOCOL_VERSION_4)
+ if (vmbus_proto_version < VERSION_WIN10)
netvsc_teardown_gpadl(device, net_device);
/* Now, we can close the channel safely */
vmbus_close(device->channel);
- if (net_device->nvsp_version >= NVSP_PROTOCOL_VERSION_4)
+ if (vmbus_proto_version >= VERSION_WIN10)
netvsc_teardown_gpadl(device, net_device);
/* Release all resources */