bnxt_en: Eliminate unintended link toggle during FW reset
authorMichael Chan <michael.chan@broadcom.com>
Sat, 5 Mar 2022 08:54:39 +0000 (03:54 -0500)
committerDavid S. Miller <davem@davemloft.net>
Sat, 5 Mar 2022 11:16:56 +0000 (11:16 +0000)
commit8bf2006064061f24c0d6115628c0ea06c894e6f0
treef2689f1bd35a10b05769b528bbcc58c3e6ee3b8e
parentdb31594e9891c8d21cd4935a636ecca343bd2dc9
bnxt_en: Eliminate unintended link toggle during FW reset

If the flow control settings have been changed, a subsequent FW reset
may cause the ethernet link to toggle unnecessarily.  This link toggle
will increase the down time by a few seconds.

The problem is caused by bnxt_update_phy_setting() detecting a false
mismatch in the flow control settings between the stored software
settings and the current FW settings after the FW reset.  This mismatch
is caused by the AUTONEG bit added to link_info->req_flow_ctrl in an
inconsistent way in bnxt_set_pauseparam() in autoneg mode.  The AUTONEG
bit should not be added to link_info->req_flow_ctrl.

Reviewed-by: Colin Winegarden <colin.winegarden@broadcom.com>
Reviewed-by: Pavan Chebbi <pavan.chebbi@broadcom.com>
Signed-off-by: Michael Chan <michael.chan@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/broadcom/bnxt/bnxt_ethtool.c