]> git.baikalelectronics.ru Git - kernel.git/commit
dp83640: Program pulsewidth2 values of perout triggers 0 and 1
authorStefan Sørensen <stefan.sorensen@spectralink.com>
Fri, 27 Jun 2014 10:05:29 +0000 (12:05 +0200)
committerDavid S. Miller <davem@davemloft.net>
Wed, 2 Jul 2014 01:52:53 +0000 (18:52 -0700)
commit1c68a32a3aea731c2e316d4776b9d4c97e29a0b9
treec4a1acb5604427cc20601019d73077f70078a130
parent815dc1d6cbe7e58b04772402b6218d383007ee97
dp83640: Program pulsewidth2 values of perout triggers 0 and 1

Periodic output triggers 0 and 1 of the dp83640 has a programmable
duty-cycle which is controlled by the Pulsewidth2 field of the trigger
data register.  This field is not documented in the datasheet, but it
is described in the "PHYTER Software Development Guide" section
3.1.4.1. Failing to set the field can result in unstable/no trigger
output.

Add programming of the Pulsewidth2 field, setting it to the same value
as the Pulsewidth field for a 50% duty cycle.

Signed-off-by: Stefan Sørensen <stefan.sorensen@spectralink.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/phy/dp83640.c